- Hardware
- SHAC-V series
Notice: Undefined offset: 3 in /www_root/html/_skin/layout/inc_navigation_middle.php on line 86
SHAC-V10,V8,V6,V4,V2
Smart evolution according to environmental changes
SHAC-V Series
Access Control Unit Download
-
- - The SHAC products are designed to be easily extensible with modules.
- - It is convenient to selectively apply as it is composed of various modules.
-
- - It stabilizes communication with the server through the network redundancy module.
- - The safety of the system operation has been secured through the redundancy of the power source.
Main features
SHAC-V Series products places the top priority on the stability in the operation of the access control system.
-
- - It is an intelligent controller with the Linux operating system.
- - We have secured communication stability with the server through network redundancy support.
- - We have secured communication security by applying encrypted communication.
-
- - If the power is cut off, the battery runs automatically to compensate for the power cut.
- - It monitors the operation of the equipment by sensing structure opening.
- - Various card readers and biometric devices can be interlocked.
Major specification
Model name | SHAC-V10 | SHAC-V8 | SHAC-V6 | SHAC-V4 | SHAC-V2 |
---|---|---|---|---|---|
OS | Linux 2.6 | ||||
CPU | ARM9 / 200 Mips | ||||
Flash Memory | 256 MB (Supports an upgrade to 16G by installing CF memory card) | ||||
Interface | TCP/IP operating environment / 100M Base T | ||||
Number of stored files | 250,000 users registered / 100,000 events saved | ||||
Transmission speed | 3 minutes for transmitting 100,000 users | ||||
Protocol support | Available on various readers (RF/fingerprint/iris/vein/face recognition) | ||||
Communication password | Communication password - AES encryption algorithm used (256bit) / Network password - HTTPS communication encryption | ||||
Expanded ports | RS-232C / RS485 | ||||
Input power source | Input AC 96V ~ 240V 50~60Hz | ||||
System Power Supply | DC13.5V / 5A | ||||
Lock Power Supply | DC12V / 8.4A | ||||
Backup Battery | DC 12V /3.2A | ||||
Operating temperature/humidity | 0℃ ~ 50℃ / 5% ~ 95% | ||||
Maximum number of people to be registered | 250,000 | ||||
Protection device and alarm | Automatic battery charging / Overload and output short circuit protection circuit alarm (AC fail / battery fail) | ||||
Molded case circuit breaker | 20A | ||||
Grounding | Brass ground 3 terminals | ||||
Network redundancy availability | - | O | O | O | O |
Certification | KC : R-REM-RF1-SHAC-V10 / CE : STD-CE-19091 | ||||
Card Reader Port | 10 | 8 | 6 | 4 | 2 |
In/Out port | 40 / 22 | 33 / 18 | 26 / 14 | 19 / 10 | 7 / 4 |
Dimensions | 800mm(H) / 500mm(W) / 150mm(D) | 610mm(H) / 500mm(W) / 150mm(D) | 450mm(H) / 350mm(W) / 150mm(D) |